1527-3

Filters and Networks

FILTER,BAND PASS

1527-3

5915-00-103-0275

5915 - Filters and Networks

Magnetika Inc

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Load Impedance Per Function

    2.2 kilohms 2nd band pass

  • Reference Frequency Per Function

    469.751 single radio interference pulses per second

  • Functional Terminal Type And Quantity

    2 pin input 1st function

  • Body Width

    1.000 inches maximum

  • Functional Terminal Type And Quantity

    2 pin output 2nd function

  • Load Impedance Per Function

    2.2 kilohms 1st band pass

  • Inclosure Type

    hermetically sealed

  • Body Height

    1.000 inches maximum

  • Body Length

    2.000 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.600 inches nominal

  • Nominal Thread Size

    0.112 inches

  • Mounting Facility Screw Thread Series Designator

    unc

  • Frequency Band Width Per Function

    469.726 kilohertz 2nd band pass and 469.776 kilohertz 2nd band pass

  • Mounting Facility Type And Quantity

    2 threaded stud

  • Specified Frequencies Of Discrimination Per Function

    469.776 kilohertz 2nd band pass and 469.726 kilohertz 2nd band pass and 469.501 kilohertz 2nd band pass and 470.001 kilohertz 2nd band pass

  • Maximum Dielectric Withstanding Ac Rms Voltage

    50.0 volts at sea level

  • Source Impedance Rating Per Function

    2.2 kilohms 2nd band pass

  • Source Impedance Rating Per Function

    2.2 kilohms 1st band pass

  • Frequency Band Width Per Function

    469.726 kilohertz 1st band pass and 469.776 kilohertz 1st band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 maximum 2nd band pass and 20.0 minimum 2nd band pass and 3.0 maximum 2nd band pass and 20.0 minimum 2nd band pass

  • Principal Circuitry Type Per Function

    crystal 2nd band pass

  • Style Designator

    rectangular terminal/terminals on one surface

  • Body Material

    metal

  • Principal Circuitry Type Per Function

    crystal 1st band pass

  • Operating Temp Range

    -0.0/+60.0 deg celsius

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.5 2nd band pass

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.600 inches nominal

  • Specified Frequencies Of Discrimination Per Function

    469.726 kilohertz 1st band pass and 469.776 kilohertz 1st band pass and 469.501 kilohertz 1st band pass and 470.001 kilohertz 1st band pass

  • Reference Frequency Per Function

    469.751 single radio interference two phase to two phase

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.5 1st band pass

  • Functional Terminal Type And Quantity

    3 pin ground 3rd function

  • Overall Height

    1.420 inches nominal

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 maximum 1st band pass and 20.0 minimum 1st band pass and 3.0 maximum 1st band pass and 20.0 minimum 1st band pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...