555260-036
Circuit Breakers
CIRCUIT BREAKER
555260-036
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Body Length
1.562 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
-
Frequency In Hertz
400.0 all locations
-
Specification/Standard Data
81349-mil-c-39019/3 government specification
-
Thread Series Designator
unef
-
Body Width
1.281 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations
-
Actuator Position Designation
between pole one and two
-
Manual Actuator Type And Quantity
1 toggle
-
Case Material
metal
-
Body Style
multipole-single actuator type
-
Terminal Type And Quantity
4 wire hook
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Trip Release Method
magnetic all locations
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Thread Quantity Per Inch
32
-
Nominal Thread Size
0.375 inches
-
Inclosure Protection Type For Which Designed
fungus resistant and hermetically sealed
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations
-
Internal Trip Release Configuration
series trip all locations
-
Mounting Surface To Terminal End Distance
1.828 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct all locations and 0.240 maximum at 400 pct all locations
-
Actuator Function
trip-reset
-
Trip Release Characteristic
time delay all locations
-
Storage Type
general purpose warehouse
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Center To Center Distance Between Terminals Parallel To Width
0.594 inches minimum and 0.656 inches maximum
-
Reset Method
manual
-
Bushing Length
0.332 inches minimum and 0.380 inches maximum
-
Pole Quantity
2
-
Circuit Protection Type
overcurrent all locations
-
Special Handling Feature
magnetic
-
Fragility Factor
moderately rugged
-
~1
data on certain environmental and performanc