AM12-10-250-50-60-39

Circuit Breakers

CIRCUIT BREAKER

AM12-10-250-50-60-39

5925-00-104-1312

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    explosion resistant

  • Frequency In Hertz

    60.0 single location

  • Thread Series Designator

    unc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.481 inches maximum

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Body Style

    12a single pole type

  • Terminal Type And Quantity

    2 threaded stud

  • Trip Delay Time In Seconds Per Rated Continuous Current

    11.500 minimum at 200 pct single location and 100.200 maximum at 200 pct

  • Actuator Position Designation

    at pole one

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay single location

  • Circuit Protection Type

    overcurrent single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...