AM33HKMG6-3.5-250-400-16

Circuit Breakers

CIRCUIT BREAKER

AM33HKMG6-3.5-250-400-16

5925-00-104-1317

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Position Designation

    at each pole

  • Auxiliary Switch Function And Quantity

    1 control

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct and 0.900 maximum at 200 pct

  • Switch Terminal Type

    tab,solder lug

  • Switch Current Rating And Type In Amps

    5.0 ac

  • Frequency In Hertz

    400.0

  • Terminal Type And Quantity

    4 threaded stud

  • Body Length

    2.530 inches nominal

  • Body Width

    1.530 inches nominal

  • Case Material

    plastic

  • Switch Contact Arrangement

    single pole,double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Mounting Surface To Terminal End Distance

    2.630 inches nominal

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Storage Type

    general purpose warehouse

  • Trip Release Method

    magnetic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Ultimate Trip Time Per Pole In Seconds

    1.000 minimum and 8.000 maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    2 toggle

  • External Actuator Linkage Arrangement

    one and two linked

  • Internal Trip Release Configuration

    series trip

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Switch Voltage Rating And Type In Volts

    125.0 ac

  • Thread Series Designator

    unc

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    any acceptable

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches nominal

  • Boss Height

    0.150 inches nominal

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    3.5 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Actuator Function

    trip-reset

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.