27519-1
Coils and Transformers
TRANSFORMER,POWER
27519-1
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Shielding Method
core grounded single component
-
Winding Operating Voltage
40.00 ac volts nominal single component single secondary
-
Inclosure Type
partially inclosed
-
Mounting Facility Quantity
2 single group
-
Frequency Rating
60.0 hertz minimum single component and 400.0 hertz maximum single component
-
Winding Operating Current
200.0 milliamperes ac maximum single component single secondary
-
Body Height
2.375 inches nominal
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Mounting Hole Diameter
0.187 inches nominal single group
-
Terminal Type And Quantity
5 tab, solder lug
-
Mounting Method
bracket single group and unthreaded hole single group
-
Reliability Indicator
not established
-
Body Length
2.000 inches maximum
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Body Width
1.953 inches nominal
-
Distance Between Mounting Facility Centers
2.375 inches nominal single mounting facility single center group
-
Adjustment Device Drive Type
shaft single component
-
Adjustment Method And Quantity
1 adjustable control single component