NF10432-21
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
NF10432-21
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
-
Operating Current Rating Per Function In Amps
22.5 1st radio interference
-
Operating Current Rating Per Function In Amps
22.5 2nd radio interference
-
Operating Current Rating Per Function In Amps
22.5 3rd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Mounting Facility Screw Thread Series Designator
unf
-
Body Width
5.938 inches minimum and 6.062 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.430 inches minimum and 4.450 inches maximum
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Functional Terminal Type And Quantity
3 tab, solder lug input
-
Operating Voltage Rating And Type Per Function
220.0 volts ac 1st radio interference and 400.0 volts dc 1st radio interference
-
Nominal Thread Size
0.190 inches
-
Maximum Dielectric Withstanding Dc Voltage
800.0 volts at sea level
-
Overall Length
5.125 inches maximum
-
Overall Height
1.188 inches minimum and 1.312 inches maximum
-
Overall Width
7.188 inches nominal
-
Body Length
3.438 inches minimum and 3.562 inches maximum
-
Operating Temp Range
-10.0 to 85.0 deg celsius
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Inclosure Type
hermetically sealed
-
Mounting Facility Type And Quantity
2 threaded stud
-
Functional Terminal Type And Quantity
3 tab, solder lug output
-
Maximum Dielectric Withstanding Ac Rms Voltage
440.0 volts at sea level
-
Operating Voltage Rating And Type Per Function
220.0 volts ac 2nd radio interference and 400.0 volts dc 2nd radio interference
-
Operating Voltage Rating And Type Per Function
220.0 volts ac 3rd radio interference and 400.0 volts dc 3rd radio interference
-
Style Designator
1 rectangular terminal/terminals on opposite surfaces