Technical Characteristics

  • Circuit Protection Type

    overcurrent all locations

  • Nominal Thread Size

    0.190 inches

  • Reset Method

    manual

  • Features Provided

    adjustable trip release

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations and 250.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Thread Series Designator

    unf

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Inclosure Protection Type For Which Designed

    moisture resistant and fungus resistant and shockproof

  • Body Width

    4.500 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac all locations and 100.0 amperes dc all locations

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Body Style

    multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    5.125 inches nominal

  • Body Height

    3.594 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Main Contact Tripping Mechanism Type

    trip free

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +1200.0/+1400.0 ac all locations and +1200.0/+1400.0 dc all locations

  • Boss Height

    0.219 inches nominal

  • Body Length

    6.000 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.594 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    120.0 all locations

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    instantaneous all locations

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    4 threaded stud

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations and 10000.0 dc all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...