27-10012-2
Circuit Breakers
CIRCUIT BREAKER
27-10012-2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Bushing Length
0.250 inches nominal
-
Thread Series Designator
unc
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Length
1.187 inches nominal
-
Trip Release Ambient Temp Rating
25.0 deg celsius maximum single location
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes dc single location
-
Actuator Function
trip-reset
-
Mounting Facility Type And Quantity
2 threaded hole
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.817 inches nominal
-
Thread Quantity Per Inch
32
-
Mounting Surface To Terminal End Distance
2.000 inches maximum
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
6000.0 dc single location
-
Pole Quantity
1
-
Internal Trip Release Configuration
series trip single location
-
Case Material
plastic
-
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc single location
-
Body Width
0.750 inches maximum
-
Terminal Type And Quantity
2 tab w/screw
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Body Length
2.187 inches maximum
-
Body Style
single pole type
-
Trip Delay Time In Seconds Per Rated Continuous Current
27.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location
-
Inclosure Protection Type For Which Designed
general purpose
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Release Characteristic
time delay single location
-
Nominal Thread Size
0.138 inches