SM33-5DC1

Circuit Breakers

CIRCUIT BREAKER

SM33-5DC1

5925-00-111-4756

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    4 wire hook

  • Non-Definitive Government Spec/Std Reference

    milc39019-3

  • Manufacturers Code

    81349

  • Definitive Government Spec/Std Reference

    m39019-3-42

  • Frequency In Hertz

    60.0 all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct and 9.000 maximum at 200 pct all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc all locations

  • Case Material

    metal

  • Body Length

    1.562 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc all locations

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Pole Quantity

    2

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Body Width

    1.281 inches maximum

  • Bushing Length

    0.380 inches maximum

  • Body Style

    1b multipole-single actuator type

  • Thread Series Designator

    unef

  • Test Data Document

    81349-mil-c-39019 specification

  • Nominal Thread Size

    0.375 inches

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Time Per Pole In Seconds

    3.000 minimum and 60.000 maximum all locations

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Method

    magnetic all locations

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...