71-161-3MG6

Circuit Breakers

CIRCUIT BREAKER

71-161-3MG6

5925-00-112-3459

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unc

  • Frequency In Hertz

    60.0

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Switch Location And Position Designation

    internal at each pole

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    120.0

  • Trip Release Characteristic

    instantaneous all locations

  • Circuit Protection Type

    overcurrent single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Pole Quantity

    2

  • Boss Height

    0.140 inches nominal

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Case Material

    plastic

  • Terminal Type And Quantity

    4 threaded stud

  • Unpackaged Unit Weight

    0.547 pounds

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Switch Terminal Type

    tab, solder lug

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Auxiliary Switch Function And Quantity

    2 alarm

  • External Actuator Linkage Arrangement

    one and two linked

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    2 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Trip Release Method

    magnetic-hydraulic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    8.5 amperes ac all locations

  • Special Handling Feature

    magnetic

  • Arc Quenching Method

    magnetic blowout

  • Mounting Surface To Terminal End Distance

    2.549 inches minimum and 2.673 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Body Width

    1.500 inches nominal

  • Body Length

    2.500 inches nominal

  • Body Style

    8c multipole-multiple actuator type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...