6042H250

Relays and Solenoids

RELAY,ELECTROMAGNETIC

6042H250

5945-00-113-0406

5945 - Relays and Solenoids

Drs Power & Control Technologies

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Operating Voltage Rating And Type At Specified Temp

    28.0 volts teardrop, two holes type 4f single winding

  • Mounting Facility Type And Quantity

    4 unthreaded hole single mounting facility

  • Time Delay

    0.025 seconds maximum fixed release time

  • Mounting Facility Pattern

    rectangular single mounting facility

  • Storage Type

    general purpose warehouse

  • Main Contact Load Current Rating At Maximum Rated Voltage

    100.0 amperes ac resistive load and 100.0 amperes dc resistive load

  • Auxiliary Contact Load Current Rating At Maximum Rated Voltage

    5.0 amperes ac resistive load and 5.0 amperes dc resistive load

  • Environmental Protection

    hermetic

  • Auxiliary Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Winding Dc Resistance Rating

    55.0 ohms nominal single winding

  • Arc Quenching Method

    air

  • Winding Quantity

    1

  • Auxiliary Contact Load Current Rating At Maximum Rated Voltage

    750.0 milliamperes ac lamp load and 750.0 milliamperes dc lamp load

  • Cubic Measure

    99.203 cubic inches

  • Overall Height

    5.615 inches maximum

  • Case Material

    metal

  • Time Delay

    0.06 seconds maximum fixed operate time

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    3.687 inches nominal single mounting facility

  • Auxiliary Contact Load Current Rating At Maximum Rated Voltage

    5.0 amperes ac inductive load and 5.0 amperes dc inductive load

  • Unthreaded Mounting Hole Diameter

    0.218 inches nominal single mounting facility

  • Main Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Nonpile-Up Auxiliary Contact Arrangement

    1 pole, single throw, normally closed, double break, momentary action and 1 pole, single throw, normally open, double make, momentary action

  • Main Contact Load Current Rating At Maximum Rated Voltage

    100.0 amperes dc inductive load

  • Terminal Type And Quantity

    12 threaded stud all functions

  • Purpose For Which Designed

    general

  • Overall Width

    3.365 inches maximum

  • Coil Quantity

    1

  • Overall Length

    4.250 inches maximum

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    3.500 inches nominal single mounting facility

  • Duty Type

    continuous

  • Main Contact Load Current Rating At Maximum Rated Voltage

    100.0 amperes ac motor load and 100.0 amperes dc motor load

  • Nonpile-Up Main Contact Arrangement

    3 pole, single throw, normally open, double make, momentary action

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...