Technical Characteristics

  • Case Material

    plastic

  • Mounting Surface To Terminal End Distance

    1.812 inches nominal

  • Pole Quantity

    1

  • Iii Arc Quenching Method

    air

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Iii Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac and 6000.0 dc single location

  • Trip Release Method

    thermal single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Thread Series Designator

    uns

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Style

    1a single pole type

  • Bushing Length

    0.250 inches nominal

  • Body Length

    1.094 inches nominal

  • Body Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    0.704 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac and 30.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac and 32.0 dc single location

  • Iii Unpackaged Unit Weight

    2.000 ounces

  • Frequency In Hertz

    400.0 single location

  • Inclosure Protection Type For Which Designed

    shockproof and vibrationproof

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct and 55.000 maximum at 200 pct single location

  • Nominal Thread Size

    0.469 inches

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...