X0415-90-240VAC60C9

Circuit Breakers

CIRCUIT BREAKER

X0415-90-240VAC60C9

5925-00-116-2664

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    4.740 inches minimum and 4.760 inches maximum

  • Body Width

    1.020 inches minimum and 1.040 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    4.370 inches minimum and 4.390 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    90.0 amperes ac single location

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Frequency In Hertz

    60.0 single location

  • Unpackaged Unit Weight

    0.688 pounds

  • Body Style

    8a single pole type

  • Body Height

    2.370 inches minimum and 2.390 inches maximum

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct single location and 100.500 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    general purpose

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 bus bar

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...