40399
Filters and Networks
FILTER,BAND PASS
40399
Coast/Advanced Chip Magnetics Inc.
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Style Designator
2 rectangular terminal/terminals on one surface
-
Maximum Dielectric Withstanding Dc Voltage
350.0 volts at sea level
-
Discrimination At Specified Frequencies Per Function In Decibels
22.3 minimum 2nd band pass and 0.2 maximum 2nd band pass and 0.2 maximum 2nd band pass and 22.3 minimum 2nd band pass
-
Frequency Band Width Per Function
85.00 hertz 1st band pass and 95.00 hertz 1st band pass
-
Frequency Band Width Per Function
142.00 hertz 2nd band pass and 158.00 hertz 2nd band pass
-
Body Material
metal
-
Specified Frequencies Of Discrimination Per Function
55.00 hertz 1st band pass and 85.00 hertz 1st band pass and 95.00 hertz 1st band pass and 150.00 hertz 1st band pass
-
Functional Terminal Type And Quantity
4 tab, solder lug input
-
Functional Terminal Type And Quantity
2 tab, solder lug output
-
Insertion Loss At Reference Frequency Per Function In Decibels
0.2 2nd band pass
-
Inclosure Type
encased
-
Output Impedance Per Function W/Source Across Input
250.0 ohms 2nd band pass
-
Input Impedance Per Function W/Load
250.0 ohms 2nd band pass
-
Source Impedance Rating Per Function
100.0 ohms 1st band pass
-
Reference Frequency Per Function
90.0 hertz 1st band pass
-
Reference Frequency Per Function
150.0 hertz 2nd band pass
-
Operating Temp Range
-55.0 to 85.0 deg celsius
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.500 inches nominal
-
Overall Height
1.950 inches maximum
-
Unpackaged Unit Weight
14.600 ounces
-
Discrimination At Specified Frequencies Per Function In Decibels
22.3 minimum 1st band pass and 0.2 maximum 1st band pass and 0.2 maximum 1st band pass and 22.3 minimum 1st band pass
-
Nominal Thread Size
0.112 inches
-
Specified Frequencies Of Discrimination Per Function
90.00 hertz 2nd band pass and 142.00 hertz 2nd band pass and 158.00 hertz 2nd band pass and 250.00 hertz 2nd band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
0.2 1st band pass
-
Mounting Facility Type And Quantity
4 threaded stud
-
Mounting Facility Screw Thread Series Designator
unc
-
Output Impedance Per Function W/Source Across Input
250.0 ohms 1st band pass
-
Input Impedance Per Function W/Load
250.0 ohms 1st band pass
-
Load Impedance Per Function
220.0 ohms 2nd band pass
-
Load Impedance Per Function
220.0 ohms 1st band pass
-
Source Impedance Rating Per Function
100.0 ohms 2nd band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.500 inches nominal
-
Vibration Resistance Range In Hertz
10.0 to 500.0
-
Body Height
1.660 inches nominal
-
Body Width
1.950 inches nominal
-
Body Length
2.950 inches nominal