SMA717609

Circuit Breakers

CIRCUIT BREAKER

SMA717609

5925-00-124-9613

5925 - Circuit Breakers

Us Army Communications &

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    0.980 inches minimum and 1.000 inches maximum

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Trip Delay Time In Seconds Per Rated Continuous Current

    35.000 minimum at 200 pct single location and 105.000 maximum at 200 pct single location

  • Boss Height

    0.146 inches minimum and 0.166 inches maximum

  • Switch Voltage Rating And Type In Volts

    125.0 ac

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 ac single location

  • Terminal Type And Quantity

    2 threaded stud

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Thread Series Designator

    unc

  • Switch Current Rating And Type In Amps

    5.0 ac

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    3.167 inches minimum and 3.259 inches maximum

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Length

    3.053 inches minimum and 3.073 inches maximum

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Switch Contact Arrangement

    single pole, double throw

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Body Length

    3.709 inches minimum and 3.729 inches maximum

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac single location

  • Body Style

    single pole type

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location

  • Switch Terminal Type

    pin

  • Frequency In Hertz

    60.0 single location

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.