APL11-314-1
Circuit Breakers
CIRCUIT BREAKER
APL11-314-1
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.160 minimum at 200 pct and 0.600 maximum at 200 pct
-
Body Length
2.490 inches nominal
-
Body Width
1.530 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
-
Boss Height
0.125 inches minimum and 0.155 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes dc
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc
-
Trip Release Characteristic
time delay
-
Reset Method
manual
-
Terminal Type And Quantity
4 threaded stud
-
Thread Pitch Diameters
p0.1177/p0.1214 inches
-
Body Style
multipole-multiple actuator type
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
1.924 inches minimum and 1.952 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Mounting Surface To Terminal End Distance
2.501 inches maximum
-
Pole Quantity
2
-
Mounting Facility Type And Quantity
4 threaded hole
-
Thread Quantity Per Inch
32
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc
-
Circuit Protection Type
overcurrent
-
Trip Release Method
magnetic
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0
-
Main Contact Tripping Mechanism Type
trip free
-
Internal Trip Release Configuration
series trip
-
Thread Series Designator
unc