2638051-44

Circuit Breakers

CIRCUIT BREAKER

2638051-44

5925-00-132-1176

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Body Width

    1.281 inches nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct all locations

  • Storage Type

    general purpose warehouse

  • Switch Terminal Type

    wire hook

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc all locations

  • Mounting Surface To Terminal End Distance

    1.828 inches nominal

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Terminal Type And Quantity

    4 wire hook

  • Switch Contact Arrangement

    single pole, double throw

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc all locations

  • Ultimate Trip Time Per Pole In Seconds

    0.200 minimum all locations and 7.000 maximum all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches nominal

  • Thread Series Designator

    unef

  • Bushing Length

    0.330 inches nominal

  • Body Length

    1.562 inches nominal

  • Switch Current Rating And Type In Amps

    1.0 ac and 0.5 dc

  • Switch Location And Position Designation

    internal at pole one

  • Auxiliary Switch Function And Quantity

    1 control

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...