81006313-001

Circuit Breakers

CIRCUIT BREAKER

81006313-001

5925-00-132-2203

5925 - Circuit Breakers

Trans-Aero Industries Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    1.110 inches minimum and 1.140 inches maximum

  • Switch Current Rating And Type In Amps

    4.0 ac and 4.0 dc

  • Maximum Continuous Load Current Rating Per Pole

    50.0 milliamperes ac single location and 50.0 milliamperes dc single location

  • Reset Method

    manual

  • Auxiliary Switch Function And Quantity

    2 alarm

  • Switch Terminal Type

    turret

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Thread Quantity Per Inch

    32

  • Terminal Type And Quantity

    2 solder stud

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Body Width

    0.635 inches maximum

  • Manual Actuator Type And Quantity

    1 push-pull

  • Switch Voltage Rating And Type In Volts

    130.0 ac and 28.0 dc

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    1.753 inches maximum

  • Inclosure Protection Type For Which Designed

    vibration resistant and shock resistant and corrosion resistant and moisture resistant and fungus resistant and sand resistant and dusttight

  • Internal Trip Release Configuration

    series trip single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 2500.0 dc single location

  • Body Style

    single pole type

  • Body Length

    1.765 inches maximum

  • Trip Release Method

    magnetic-hydraulic single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • Frequency In Hertz

    60.0 single location

  • Trip Release Characteristic

    instantaneous single location

  • Unpackaged Unit Weight

    2.000 ounces

  • Nominal Thread Size

    0.469 inches

  • Bushing Length

    0.319 inches minimum

  • Switch Location And Position Designation

    internal at pole one

  • Thread Series Designator

    uns

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...