Technical Characteristics

  • Overall Height

    0.890 inches minimum and 0.900 inches maximum

  • Overall Width

    0.390 inches minimum and 0.400 inches maximum

  • Fragility Factor

    moderately rugged

  • Winding Quantity

    1

  • Winding Dc Resistance Rating

    540.0 ohms minimum single winding and 660.0 ohms maximum

  • Duty Type

    continuous

  • Mounting Facility Type And Quantity

    1 plug-in terminal second mounting facility

  • Mounting Facility Type And Quantity

    2 unthreaded hole first mounting facility

  • Mounting Facility Pattern

    two position in-line first mounting facility

  • Nonpile-Up Main Contact Arrangement

    2 pole, double throw, one position momentary

  • Time Delay

    0.005 seconds maximum fixed operate time

  • Operating Voltage Rating And Type At Specified Temp

    13.5 volts dc 25 deg celsius single winding

  • Main Contact Load Current Rating At Maximum Rated Voltage

    1.0 amperes dc inductive load

  • Main Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Terminal Type And Quantity

    8 pin all functions

  • Overall Length

    1.320 inches minimum and 1.330 inches maximum

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    1.073 inches minimum first mounting facility and 1.083 inches maximum

  • Environmental Protection

    hermetic

  • Unthreaded Mounting Hole Diameter

    0.115 inches minimum first mounting facility and 0.125 inches maximum

  • Purpose For Which Designed

    general

  • Coil Quantity

    1

  • Arc Quenching Method

    air

  • Storage Type

    general purpose warehouse

  • Cubic Measure

    0.468 cubic inches

  • Time Delay

    0.004 seconds maximum fixed release time

  • Main Contact Load Current Rating At Maximum Rated Voltage

    1.0 amperes ac resistive load and 2.0 amperes dc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.