MIL-C-5809
Circuit Breakers
CIRCUIT BREAKER
MIL-C-5809
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Maximum Continuous Load Current Rating Per Pole
4.0 amperes ac single location and 4.0 amperes dc single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
145.0 single location
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Manual Actuator Type And Quantity
1 push-pull
-
Pole Quantity
1
-
Case Material
metal
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Terminal Type And Quantity
2 screw
-
Mounting Surface To Terminal End Distance
1.812 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Bushing Length
0.273 inches minimum and 0.293 inches maximum
-
Inclosure Protection Type For Which Designed
moisture resistant and dustproof and corrosion resistant and fungus resistant and explosion proof and sand resistant
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Body Length
0.780 inches maximum
-
Specification/Standard Data
96906-ms22073 government standard
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
800.0 ac single location and 2000.0 dc single location
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 120.0 dc single location
-
Body Width
0.593 inches maximum
-
Test Data Document
81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performance
-
Center To Center Distance Between Terminals Parallel To Length
0.672 inches minimum and 0.734 inches maximum
-
Internal Trip Release Configuration
series trip single location
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Nominal Thread Size
0.469 inches
-
Thread Series Designator
uns