6250F56-1
Switches
SWITCH,FLOW
6250F56-1
SWITCH,FLOW
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Quantity Per Inch
14 second pressure connection
-
Media For Which Designed
liquid
-
Thread Quantity Per Inch
14 first pressure connection
-
Nominal Thread Size
0.500 inches first pressure connection
-
Thread Series Designator
npt first pressure connection
-
Contact Adjustability
actuation point not adjustable and deactuation point not adjustable
-
Overall Length
3.250 inches maximum
-
Nominal Thread Size
0.500 inches second pressure connection
-
Features Provided
hermetically sealed case
-
Nonpile-Up Contact Arrangement
1 pole, double throw, both positions maintained
-
Contact Voltage Rating In Volts
250.0 ac at sea level second voltage
-
Contact Load Current Rating
7.0 amperes resistive load first voltage
-
Special Features
90.0 psig system pressure; 125.0 psig proof pressure; pressure drop not to exceed 6 psi at flow rate of 1.0 gpm
-
Contact Voltage Rating In Volts
125.0 ac at sea level first voltage
-
Contact Stimulus Rating
0.91 actuation point nominal gallons per minute and 0.75 deactuation point nominal gallons per minute
-
Mounting Method
input port
-
Contact Load Current Rating
7.0 amperes resistive load second voltage
-
Overall Width
2.620 inches nominal
-
Thread Series Designator
npt second pressure connection
-
Terminal Type
wire loop
-
Contact Action Stimulus
increase