1200-015-5

Circuit Breakers

CIRCUIT BREAKER

1200-015-5

5925-00-135-3440

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    series trip single location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 push-pull

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Thread Quantity Per Inch

    32

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.270 minimum at 200 pct single location and 0.550 maximum at 200 pct single location

  • Terminal Type And Quantity

    2 screw

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Center To Center Distance Between Terminals Parallel To Length

    1.187 inches nominal

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Inclosure Protection Type For Which Designed

    dustproof

  • Bushing Length

    0.250 inches nominal

  • Case Material

    plastic

  • Body Width

    0.750 inches maximum

  • Body Length

    2.187 inches maximum

  • Body Style

    single pole type

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac single location and 6000.0 dc single location

  • Frequency In Hertz

    400.0 single location

  • Mounting Facility Type And Quantity

    2 threaded stud

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.822 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Nominal Thread Size

    0.138 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...