Technical Characteristics

  • Bushing Length

    0.040 inches minimum and

  • Bushing Length

    0.055 inches maximum

  • Body Length

    0.719 inches minimum and

  • Body Length

    0.781 inches maximum

  • Case Material

    plastic

  • Mounting Surface To Terminal End Distance

    1.343 inches maximum

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac and

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac and

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Time Per Pole In Seconds

    16.000 maximum single location

  • Ultimate Trip Time Per Pole In Seconds

    4.000 minimum and

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 push-pull

  • Nominal Thread Size

    0.438 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    16.000 maximum at 200 pct single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct and

  • Inclosure Protection Type For Which Designed

    general purpose

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Frequency In Hertz

    400.0 single location

  • Iii Unpackaged Unit Weight

    0.057 pounds

  • Body Style

    1a single pole type

  • Terminal Type And Quantity

    2 tab w/screw

  • Thread Series Designator

    uns

  • Internal Trip Release Configuration

    series trip single location

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Method

    thermal single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    6000.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac and

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc single location

  • Thread Quantity Per Inch

    32

  • Iii Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Mounting Surface To Terminal End Distance

    1.281 inches minimum and

  • Iii Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Length

    0.531 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.469 inches minimum and

  • Body Width

    0.593 inches maximum

  • Body Width

    0.531 inches minimum and

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...