Technical Characteristics
-
Bushing Length
0.040 inches minimum and
-
Bushing Length
0.055 inches maximum
-
Body Length
0.719 inches minimum and
-
Body Length
0.781 inches maximum
-
Case Material
plastic
-
Mounting Surface To Terminal End Distance
1.343 inches maximum
-
Pole Quantity
1
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac and
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac and
-
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location
-
Circuit Protection Type
overcurrent single location
-
Ultimate Trip Time Per Pole In Seconds
16.000 maximum single location
-
Ultimate Trip Time Per Pole In Seconds
4.000 minimum and
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 push-pull
-
Nominal Thread Size
0.438 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
16.000 maximum at 200 pct single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct and
-
Inclosure Protection Type For Which Designed
general purpose
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Frequency In Hertz
400.0 single location
-
Iii Unpackaged Unit Weight
0.057 pounds
-
Body Style
1a single pole type
-
Terminal Type And Quantity
2 tab w/screw
-
Thread Series Designator
uns
-
Internal Trip Release Configuration
series trip single location
-
Actuator Position Designation
at pole one
-
Actuator Function
trip-reset
-
Reset Method
manual
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Trip Release Characteristic
time delay single location
-
Trip Release Method
thermal single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
6000.0 dc single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 ac and
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes dc single location
-
Thread Quantity Per Inch
32
-
Iii Storage Type
general purpose warehouse
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Mounting Surface To Terminal End Distance
1.281 inches minimum and
-
Iii Fragility Factor
moderately rugged
-
Center To Center Distance Between Terminals Parallel To Length
0.531 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
0.469 inches minimum and
-
Body Width
0.593 inches maximum
-
Body Width
0.531 inches minimum and