168860-1
Circuit Breakers
CIRCUIT BREAKER
168860-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
Internal Trip Release Configuration
series trip single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.090 minimum at 200 pct and 0.610 maximum at 200 pct single location
-
Inclosure Protection Type For Which Designed
dustproof and hermetically sealed
-
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc
-
Frequency In Hertz
400.0
-
Terminal Type And Quantity
2 wire hook
-
Thread Series Designator
unef
-
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc
-
Switch Terminal Type
tab, solder lug
-
Switch Location And Position Designation
internal at pole one
-
Nominal Thread Size
0.375 inches
-
Auxiliary Switch Function And Quantity
1 control
-
Main Contact Tripping Mechanism Type
trip free
-
Reset Method
manual
-
Trip Release Characteristic
time delay single location
-
Circuit Protection Type
overcurrent single location
-
Case Material
metal
-
Body Width
0.625 inches maximum
-
Body Length
1.500 inches maximum
-
Bushing Length
0.375 inches nominal
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Trip Release Method
magnetic single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac single location
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location
-
Thread Quantity Per Inch
32
-
Storage Type
general purpose warehouse
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Pole Quantity
1
-
Mounting Surface To Terminal End Distance
1.605 inches maximum
-
Switch Contact Arrangement
single pole, double throw
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Body Style
2a single pole type