40Z406B

Coils and Transformers

TRANSFORMER,PULSE

40Z406B

5950-00-138-2782

5950 - Coils and Transformers

Sprague Electric Co

TRANSFORMER,PULSE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    95542-151-139 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Winding Operating Voltage

    200.00 ac pounds per hour with retaining chain single component single primary

  • Overall Height

    0.375 inches maximum

  • Inductance Rating

    700.00 microhenries nominal single component single primary

  • Dc Resistance Rating In Ohms

    6.300 single component all secondary

  • Dc Resistance Rating In Ohms

    6.300 single component single primary

  • Winding Function And Quantity

    1 primary single component and 2 secondary single component

  • Primary To Secondary Turn Ratio

    1 to 1 to 1 single component

  • Inclosure Type

    fully inclosed

  • Reliability Indicator

    established

  • Special Features

    scr trigger

  • Overall Diameter

    0.610 inches maximum

  • Mounting Method

    terminal single group

  • Frequency Rating

    60.0 hertz nominal single component

  • Maximum Operating Temp

    130.0 deg celsius

  • Terminal Type And Quantity

    6 pin

  • Reliability Failure Rate Level In Percent

    0.100

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...