512338-2
Circuit Breakers
CIRCUIT BREAKER
512338-2
Naval Air Warfare Center Aircraft
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Release Characteristic
instantaneous all locations
-
Trip Release Method
magnetic all locations
-
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
-
Mounting Facility Type And Quantity
6 unthreaded hole
-
Body Style
multipole-single actuator type
-
Maximum Continuous Load Current Rating Per Pole
400.0 amperes ac all locations
-
Unthreaded Mounting Hole Diameter
0.190 inches nominal
-
Boss Height
0.156 inches nominal
-
Actuator Function
trip-reset
-
Center To Center Distance Between Terminals Parallel To Length
9.750 inches nominal
-
Actuator Position Designation
at pole two
-
Manual Actuator Type And Quantity
1 toggle
-
Body Length
11.000 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
9.000 inches nominal
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Reset Method
manual
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac all locations
-
Main Contact Tripping Mechanism Type
nontrip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Center To Center Distance Between Terminals Parallel To Width
2.125 inches nominal
-
Case Material
plastic
-
Frequency In Hertz
60.0 all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.125 inches nominal
-
Terminal Type And Quantity
6 compression
-
Body Height
4.062 inches nominal
-
Body Width
9.000 inches nominal
-
Pole Quantity
3
-
Internal Trip Release Configuration
series trip all locations
-
Circuit Protection Type
overcurrent all locations