4MC11-1-02

Circuit Breakers

CIRCUIT BREAKER

4MC11-1-02

5925-00-138-7432

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.053 inches minimum and 2.073 inches maximum

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    60.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc single location

  • Trip Release Method

    magnetic single location

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Thread Series Designator

    unc

  • Body Style

    12a single pole type

  • Body Length

    2.500 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.490 inches minimum and 1.510 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.110 inches minimum and 0.130 inches maximum

  • Mounting Surface To Terminal End Distance

    2.540 inches minimum and 2.580 inches maximum

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    20.0 milliamperes dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    instantaneous single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    relay trip single location

  • Unpackaged Unit Weight

    4.000 ounces

  • Terminal Type And Quantity

    4 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...