631225F

Circuit Breakers

CIRCUIT BREAKER

631225F

5925-00-139-2641

5925 - Circuit Breakers

Electric Construction

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Manual Actuator Type And Quantity

    1 rotary

  • Actuator Position Designation

    at pole two

  • Adjustable Trip Setting Current Range Per Pole In Amps

    p600.0/p2250.0 ac

  • Inclosure Protection Type For Which Designed

    dustproof

  • Frequency In Hertz

    60.0

  • Actuator Function

    trip-reset

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal

  • Terminal Type And Quantity

    6 compression

  • Body Style

    multipole-single actuator type

  • Body Length

    10.125 inches nominal

  • Body Width

    8.250 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    9.125 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.312 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.750 inches nominal

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.250 inches nominal

  • Pole Quantity

    3

  • Storage Type

    general purpose warehouse

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    25000.0 ac

  • Trip Release Method

    thermal-magnetic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Height

    4.375 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    2.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    9.125 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Features Provided

    adjustable trip release

  • Maximum Continuous Load Current Rating Per Pole

    225.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    instantaneous and time delay

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    80.000 minimum at 200 pct and 500.000 maximum at 200 pct

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...