11268812

Circuit Breakers

CIRCUIT BREAKER

11268812

5925-00-139-4829

5925 - Circuit Breakers

Ballistic Missile Defense Systems

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Nominal Thread Size

    0.190 inches

  • Reset Method

    manual

  • Thread Series Designator

    unf

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.062 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Actuator Position Designation

    at pole two

  • Body Length

    5.260 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • End Item Identification

    asr7

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.700 minimum at 150 pct all locations and 1.200 maximum at 150 pct all locations and 0.900 maximum at 200 pct all locations and 0.300 minimum at 200 pct all locations and 0.150 minimum at 300 pct all locations and 0.300 maximum at 300 pct all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Width

    2.984 inches nominal

  • Frequency In Hertz

    60.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.000 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Boss Height

    0.219 inches nominal

  • Mounting Surface To Terminal End Distance

    3.313 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Length

    4.359 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    8.0 amperes ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.490 inches nominal

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...