905369-2
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
905369-2
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Overall Length
3.400 inches nominal
-
Body Width
0.500 inches nominal
-
Body Height
1.500 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.500 inches nominal
-
Operating Temp Range
-54.0/+125.0 deg celsius
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference .
-
Load Impedance Per Function
50.0 ohms 1st radio interference .
-
Load Impedance Per Function
50.0 ohms 2nd radio interference .
-
Load Impedance Per Function
50.0 ohms 3rd radio interference .
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference .
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference .
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference .
-
Power Line Frequency Rating Per Function In Hertz
400.0 4th radio interference .
-
Operating Current Rating Per Function In Amps
0.6 1st radio interference .
-
Operating Current Rating Per Function In Amps
0.6 4th radio interference .
-
Maximum Voltage Drop Per Function
1.0 volts ac 1st radio interference .
-
Maximum Voltage Drop Per Function
1.0 volts ac 3rd radio interference .
-
Maximum Voltage Drop Per Function
1.0 volts ac 4th radio interference .
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Maximum Temp Rise
45.0 deg celsius
-
Mounting Facility Screw Thread Series Designator
unc
-
Inclosure Type
hermetically sealed
-
Mounting Facility Type And Quantity
4 threaded hole
-
Functional Terminal Type And Quantity
4 turret output .
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference .
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference .
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 4th radio interference .
-
Body Length
3.000 inches nominal
-
Vibration Resistance Range In Hertz
10.0/ 500.0
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.000 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference .
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference .
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference .
-
Load Impedance Per Function
50.0 ohms 4th radio interference .
-
Operating Current Rating Per Function In Amps
0.6 2nd radio interference .
-
Operating Current Rating Per Function In Amps
0.6 3rd radio interference .
-
Maximum Voltage Drop Per Function
1.0 volts ac 2nd radio interference .
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 4th radio interference
-
Functional Terminal Type And Quantity
4 turret input .
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference .
-
Nominal Thread Size
0.112 inches
-
Body Material
metal
-
Maximum Dielectric Withstanding Dc Voltage
500.0 volts at sea level
-
Body Surface Treatment
tin
-
Unpackaged Unit Weight
5.000 ounces
-
Style Designator
5 rectangular terminal/terminals on opposite surfaces