A742459-3

Filters and Networks

FILTER,BAND PASS

A742459-3

5915-00-140-1304

5915 - Filters and Networks

General Dynamics C4 Systems Inc.

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.500 inches nominal

  • Specified Frequencies Of Discrimination Per Function

    1.45 kilohertz 3rd band pass and 1.43 kilohertz 3rd band pass and 1.51 kilohertz 3rd band pass and 1.52 kilohertz 3rd band pass

  • Overall Height

    0.700 inches maximum

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th band pass

  • Reference Frequency Per Function

    2.6 single radio interference three phase to two phase

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 1st band pass and 30.0 maximum 1st band pass

  • Specified Frequencies Of Discrimination Per Function

    913.00 hertz 1st band pass and 959.00 hertz 1st band pass and 922.00 hertz 1st band pass and 970.00 hertz 1st band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 3rd band pass and 30.0 maximum 3rd band pass

  • Frequency Band Width Per Function

    2.21 kilohertz 4th band pass and 2.30 kilohertz 4th band pass

  • Frequency Band Width Per Function

    1.45 kilohertz 3rd band pass and 1.51 kilohertz 3rd band pass

  • Body Width

    2.280 inches maximum

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 4th band pass and 30.0 maximum 4th band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 3rd band pass

  • Specified Frequencies Of Discrimination Per Function

    2.21 kilohertz 4th band pass and 2.18 kilohertz 4th band pass and 2.30 kilohertz 4th band pass and 2.32 kilohertz 4th band pass

  • Body Surface Treatment

    tin

  • Specified Frequencies Of Discrimination Per Function

    2.65 kilohertz 5th band pass and 2.52 kilohertz 5th band pass and 2.55 kilohertz 5th band pass and 2.68 kilohertz 5th band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 2nd band pass

  • Frequency Band Width Per Function

    922.00 hertz 1st band pass and 959.00 hertz 1st band pass

  • Inclosure Type

    hermetically sealed

  • Functional Terminal Type And Quantity

    5 pin output 2nd function

  • Body Height

    0.510 inches maximum

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 1st band pass

  • Body Length

    4.030 inches maximum

  • Reference Frequency Per Function

    1.48 single radio interference two phase to three phase

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th band pass

  • Load Impedance Per Function

    100.0 kilohms 5th band pass

  • Source Impedance Rating Per Function

    1.0 kilohms 1st band pass

  • Specified Frequencies Of Discrimination Per Function

    1.19 kilohertz 2nd band pass and 1.23 kilohertz 2nd band pass and 1.17 kilohertz 2nd band pass and 1.25 kilohertz 2nd band pass

  • Load Impedance Per Function

    100.0 kilohms 4th band pass

  • Load Impedance Per Function

    100.0 kilohms 3rd band pass

  • Vibration Resistance Range In Hertz

    +10.0/+800.0

  • Functional Terminal Type And Quantity

    1 pin ground 3rd function

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.750 inches nominal

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 5th band pass

  • Reference Frequency Per Function

    2.25 single radio interference hertz

  • Mounting Facility Type And Quantity

    15 pin

  • Load Impedance Per Function

    100.0 kilohms 2nd band pass

  • Reference Frequency Per Function

    941.0 single high pass pulses per second

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd band pass

  • Style Designator

    rectangular terminal/terminals on one surface

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 2nd band pass and 30.0 maximum 2nd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 4th band pass

  • Body Material

    metal

  • Load Impedance Per Function

    100.0 kilohms 1st band pass

  • Operating Temp Range

    -18.0/+75.0 deg celsius

  • Unpackaged Unit Weight

    4.000 ounces

  • Source Impedance Rating Per Function

    1.0 kilohms 5th band pass

  • Frequency Band Width Per Function

    2.55 kilohertz 5th band pass and 2.65 kilohertz 5th band pass

  • Functional Terminal Type And Quantity

    2 pin input 1st function

  • Source Impedance Rating Per Function

    1.0 kilohms 4th band pass

  • Frequency Band Width Per Function

    1.19 kilohertz 2nd band pass and 1.23 kilohertz 2nd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 2nd band pass

  • Reference Frequency Per Function

    1.21 single radio interference two phase to two phase

  • Source Impedance Rating Per Function

    1.0 kilohms 3rd band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 minimum 5th band pass and 30.0 maximum 5th band pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...