160007-1
Coils and Transformers
TRANSFORMER,POWER
160007-1
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Operating Temp
130.0 deg celsius
-
Inclosure Type
hermetically sealed
-
Winding Operating Voltage
1.70 ac kilovolts nominal single component all secondary
-
Overall Length
8.970 inches minimum and 9.030 inches maximum
-
Winding Power Rating
2.125 kilovolt-amperes single component all secondary
-
Distance Between Mounting Facility Centers
7.970 inches minimum single mounting facility all center groupings and 8.030 inches maximum single mounting facility all center groupings
-
Overall Width
7.970 inches minimum and 8.030 inches maximum
-
Frequency Rating
380.0 hertz minimum single component and 420.0 hertz maximum single component
-
Cubic Measure (Non-Core)
509.7 cubic inches
-
Unpackaged Unit Weight (Non-Core)
50.000 pounds
-
Overall Height
7.030 inches maximum
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Winding Operating Current
1.25 amperes ac nominal single component all secondary
-
Input-Output Phase Relationship
three phase to three phase single component
-
Terminal Type And Quantity
17 standoff, threaded stud
-
Mounting Facility Quantity
3 all groupings
-
Winding Operating Voltage
208.00 ac volts nominal single component single primary
-
Mounting Method
unthreaded hole all groupings
-
Winding Shielding Method
internal shield brought out to terminal single component and core grounded to secondary terminal single component
-
Reliability Indicator
not established
-
Mounting Hole Diameter
0.358 inches minimum all groupings and 0.366 inches maximum all groupings