W91X15-2-20

Circuit Breakers

CIRCUIT BREAKER

W91X15-2-20

5925-00-142-0752

5925 - Circuit Breakers

Tyco Electronics Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Inclosure Protection Type For Which Designed

    shock resistant and moisture resistant and vibration resistant

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Specification/Standard Data

    81349-mil-c-55629/1 government specification

  • Body Style

    single pole type

  • Mounting Surface To Terminal End Distance

    2.475 inches nominal

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Body Width

    0.750 inches maximum

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Boss Height

    0.150 inches nominal

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Special Handling Feature

    magnetic

  • Trip Release Method

    magnetic single location

  • Fragility Factor

    moderately rugged

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 200 pct single location and 8.000 maximum at 200 pct single location

  • ~1

    data on certain environmental and performanc

  • Test Data Document

    81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...