Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    130.0 single location

  • Inclosure Protection Type For Which Designed

    dustproof

  • Thread Series Designator

    unc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    900.0 dc single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Body Length

    2.203 inches nominal

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    2 screw

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Unpackaged Unit Weight

    1.850 ounces

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.164 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 30.0 dc single location

  • Body Style

    single pole type

  • Mounting Surface To Terminal End Distance

    1.406 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    30.000 nominal at 200 pct single location

  • Frequency In Hertz

    60.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.812 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    80.0 amperes ac single location and 80.0 amperes dc single location

  • Body Width

    0.766 inches maximum

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...