95658607

Circuit Breakers

CIRCUIT BREAKER

95658607

5925-00-145-9065

5925 - Circuit Breakers

Magnetic Peripherals Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    series trip single location

  • Body Length

    1.156 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Ultimate Trip Time Per Pole In Seconds

    10.400 nominal single location

  • Body Width

    0.563 inches nominal

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Inclosure Protection Type For Which Designed

    dustproof

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    200.0 single location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.400 nominal at 200 pct single location and 3.180 nominal at 300 pct single location and 2.900 nominal at 400 pct single location

  • Manual Actuator Type And Quantity

    1 push button

  • Nominal Thread Size

    0.375 inches

  • Unpackaged Unit Weight

    1.000 ounces

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    200.0 ac single location and 200.0 dc single location

  • Thread Quantity Per Inch

    27

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location and 24.0 dc single location

  • Pole Quantity

    1

  • Terminal Type And Quantity

    3 quick disconnect, male

  • Frequency In Hertz

    400.0 single location

  • Mounting Surface To Terminal End Distance

    2.250 inches nominal

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches nominal

  • Bushing Length

    0.391 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac single location and 20.0 amperes dc single location

  • Trip Release Ambient Temp Rating

    70.0 deg fahrenheit maximum single location

  • Thread Series Designator

    uns

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...