0005-640-009

Circuit Breakers

CIRCUIT BREAKER

0005-640-009

5925-00-147-0748

5925 - Circuit Breakers

Spx Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Switch Current Rating And Type In Amps

    10.0 ac and 5.0 dc

  • Switch Terminal Type

    tab,solder lug

  • Inclosure Protection Type For Which Designed

    moisture resistant

  • Switch Location And Position Designation

    internal at pole one

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip

  • Actuator Function

    trip-reset

  • Circuit Protection Type

    overcurrent

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc

  • Thread Quantity Per Inch

    32

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    1.828 inches minimum and 1.860 inches maximum

  • Boss Height

    0.125 inches minimum and 0.155 inches maximum

  • Switch Contact Arrangement

    single pole,double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Case Material

    plastic

  • Body Style

    single pole type

  • Terminal Type And Quantity

    2 threaded stud

  • Unpackaged Unit Weight

    4.750 ounces

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct and 1.200 maximum at 200 pct

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Actuator Position Designation

    at pole one

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Characteristic

    time delay

  • Trip Release Method

    magnetic-hydraulic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes dc

  • Storage Type

    unimproved open

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Arc Quenching Method

    magnetic blowout

  • Center To Center Distance Between Terminals Parallel To Length

    1.924 inches minimum and 1.952 inches maximum

  • Body Width

    0.738 inches minimum and 0.750 inches maximum

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...