1642-25
Coils and Transformers
TRANSFORMER,RADIO FREQUENCY
1642-25
TRANSFORMER,RADIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Tab Width
0.023 inches minimum and 0.025 inches maximum
-
Rating Method
winding turns single component single primary
-
Turn Quantity
1/2 single component single primary output
-
Terminal Type And Quantity
4 pin
-
Body Length
0.490 inches maximum
-
Winding Function And Quantity
1 primary, variable autotransformer type single component
-
Turn Quantity
2-1/2 single component single primary input
-
Reliability Indicator
not established
-
Winding Conductor Size
0.00795 inches american wire gage single component single primary output
-
Winding Conductor Size
0.00795 inches american wire gage single component single primary input
-
Dummy Terminal Quantity (Non-Core)
1
-
Frequency Rating
13.0 megahertz nominal single component
-
Winding Tap Location (Non-Core)
tap w/o center tap single component single primary input
-
Inclosure Type
fully inclosed
-
Coil Form Type
hollow single component
-
Overall Diameter
0.417 inches minimum and 0.427 inches maximum
-
Mounting Method
tab single group
-
Adjustment Method And Quantity
1 adjustable core single component
-
Adjustment Device Drive Type
slotted screw single component