CD2-Z102-3

Circuit Breakers

CIRCUIT BREAKER

CD2-Z102-3

5925-00-148-8125

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Protection Type For Which Designed

    salt spray proof and moisture resistant and vibration resistant and shock resistant and fungus resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    30.000 minimum at 200 pct first location and 100.000 maximum at 200 pct first location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Mounting Slot Width

    0.164 inches nominal

  • External Actuator Linkage Arrangement

    one and two linked

  • Operating Voltage Type And Rating Per Pole In Volts

    30.0 dc second location

  • Switch Voltage Rating And Type In Volts

    125.0 ac

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Special Handling Feature

    magnetic

  • Mounting Facility Type And Quantity

    4 threaded hole and 4 slot

  • Internal Trip Release Configuration

    relay trip second location

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Unpackaged Unit Weight

    1.300 pounds

  • Manual Actuator Type And Quantity

    2 toggle

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 dc first location

  • Body Length

    4.750 inches nominal

  • Switch Current Rating And Type In Amps

    5.0 ac

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    1.026 inches nominal

  • Circuit Protection Type

    overcurrent first location

  • Storage Type

    general purpose warehouse

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc all locations

  • Actuator Function

    trip-reset

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.026 inches nominal

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Internal Trip Release Configuration

    series trip first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 first location

  • Trip Release Characteristic

    time delay first location

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes dc all locations

  • Mounting Surface To Terminal End Distance

    3.485 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Body Width

    2.072 inches maximum

  • Trip Release Characteristic

    instantaneous second location

  • Test Data Document

    80063-sm-a-742924 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Length

    3.547 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Circuit Protection Type

    overvoltage second location

  • Boss Height

    0.219 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...