L31007

Coils and Transformers

COIL,RADIO FREQUENCY

L31007

5950-00-153-9732

5950 - Coils and Transformers

Scientific Radio Systems Inc

COIL,RADIO FREQUENCY

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    0.416 inches nominal

  • Inclosure Type

    fully inclosed

  • Body Length

    0.566 inches nominal

  • Quality Factor

    55 minimum single component single winding and 60 maximum single component single winding

  • Overall Length

    0.597 inches nominal

  • Reliability Indicator

    not established

  • Terminal Type And Quantity

    2 tab, solder lug

  • Rating Method

    electrical single component single winding

  • Mounting Method

    terminal single group

  • Overall Height

    0.416 inches nominal

  • Inductance Rating

    16.50 microhenries minimum single component single winding and 35.00 microhenries maximum single component single winding

  • Frequency At Which Inductance And Quality Factor Applies (Non-Core)

    2.5 megahertz single component single winding

  • Core Construction

    powdered single component

  • Body Height

    0.416 inches nominal

  • Adjustment Device Drive Type

    slotted screw single component

  • Adjustment Method And Quantity

    1 adjustable core single component

  • Overall Width

    0.572 inches nominal

  • Coil Form Type

    hollow single component

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...