SDLM-150

Circuit Breakers

CIRCUIT BREAKER

SDLM-150

5925-00-156-4044

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    reset

  • Body Width

    1.875 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    130.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    900.0 ac single location and 900.0 dc single location

  • Mounting Surface To Terminal End Distance

    1.312 inches nominal

  • Reset Method

    manual

  • Trip Release Ambient Temp Rating

    25.0 deg celsius maximum single location

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Manual Actuator Type And Quantity

    1 push button

  • Terminal Type And Quantity

    2 screw

  • Trip Delay Time In Seconds Per Rated Continuous Current

    6.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.406 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Unpackaged Unit Weight

    5.000 ounces

  • Pole Quantity

    1

  • Operating Voltage Type And Rating Per Pole In Volts

    110.0 ac single location and 30.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    1.062 inches nominal

  • Overall Length

    3.156 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    150.0 amperes ac single location and 150.0 amperes dc single location

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...