NE231050
Circuit Breakers
CIRCUIT BREAKER
NE231050
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Type And Quantity
6 unthreaded hole
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations and 5000.0 dc all locations
-
Actuator Function
trip w/separate reset
-
Reset Method
manual
-
Overall Width
4.125 inches nominal
-
Trip Release Characteristic
time delay all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal all locations
-
Arc Quenching Method
deion
-
Manual Actuator Type And Quantity
1 toggle
-
Special Features
mtg holes in 2 rows of 3,1.375 by 4.844 in. c to c
-
Main Contact Tripping Mechanism Type
trip free
-
Terminal Type And Quantity
6 screw
-
Unthreaded Mounting Hole Diameter
0.188 inches nominal
-
Ultimate Trip Time Per Pole In Seconds
210.000 minimum all locations and 4200.000 maximum all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations and 125.0 dc all locations
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations and 15.0 amperes dc all locations
-
Overall Height
3.969 inches nominal
-
Overall Length
6.000 inches nominal
-
Case Material
plastic
-
Trip Release Method
thermal all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
8.000 minimum at 300 pct all locations and 105.000 maximum at 200 pct all locations and 20.000 minimum at 200 pct all locations and 210.000 minimum at 125 pct all locations and 4200.000 maximum at 125 pct all locations and 23.000 maximum at 300 pct all
-
~1
locations