Technical Characteristics

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • Thread Quantity Per Inch

    24

  • Body Width

    1.250 inches maximum

  • Internal Trip Release Configuration

    shunt trip second location

  • Switch Terminal Type

    pin

  • Switch Current Rating And Type In Amps

    0.500 ac

  • Inclosure Protection Type For Which Designed

    shock resistant and hermetically sealed and vibration resistant

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct second location and 6.000 maximum at 200 pct second location

  • Bushing Length

    0.332 inches minimum and 0.375 inches maximum

  • Special Features

    shunt coil rating is 0.500 amps,240 vac,60 hz

  • Switch Location And Position Designation

    internal at pole one

  • Fragility Factor

    moderately rugged

  • Nonturn Device Diameter

    0.250 inches nominal

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 32.0 dc all locations

  • Pole Quantity

    2

  • Terminal Type And Quantity

    5 wire hook

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Thread Series Designator

    unf

  • Storage Type

    general purpose warehouse

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.375 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations and 1000.0 dc all locations

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations and 20.0 amperes dc all locations

  • Trip Release Method

    magnetic all locations

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Internal Trip Release Configuration

    series trip first location

  • Switch Contact Arrangement

    single pole, double throw

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Body Style

    multipole-single actuator type

  • Nonturn Device Radius

    0.625 inches nominal

  • Trip Release Characteristic

    instantaneous first location

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Trip Release Characteristic

    time delay second location

  • Switch Voltage Rating And Type In Volts

    120.0 ac

  • Body Length

    1.500 inches maximum

  • Actuator Position Designation

    between pole one and two

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...