RF-1964
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
RF-1964
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Temp Rise
25.0 deg celsius
-
Functional Terminal Type And Quantity
1 tab, solder lug input 1st function
-
Operating Temp Range
-55.0/+125.0 deg celsius
-
Functional Terminal Type And Quantity
1 tab, solder lug output 2nd function
-
Full Load Insertion Loss Frequencies In Megahertz
100.0 and 0.5 and 0.15 and 10.0 and 1000.0 and 10000.0
-
Operating Current Rating Per Function In Amps
10.0 blank
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Nominal Thread Size
0.625 inches
-
Maximum Dielectric Withstanding Dc Voltage
1.2 kilovolts at sea level
-
Source Impedance Rating Per Function
50.0 ohms blank
-
Body Length
3.590 inches maximum
-
Overall Length
4.652 inches maximum
-
Mounting Facility Screw Thread Series Designator
unf
-
Full Load Minimum Insertion Loss At Specified Frequency In Decibels
60.0 and 80.0 and 80.0 and 80.0 and 80.0 and 80.0
-
Body Outside Diameter
1.530 inches maximum
-
Maximum Dielectric Withstanding Ac Rms Voltage
500.0 volts at sea level
-
Inclosure Type
hermetically sealed
-
Power Line Frequency Rating Per Function In Hertz
60.0 blank
-
Style Designator
round terminal/terminals on opposite surfaces
-
Load Impedance Per Function
50.0 ohms blank
-
Operating Voltage Rating And Type Per Function
250.0 volts ac blank and 600.0 volts dc blank