78-158-1

Circuit Breakers

CIRCUIT BREAKER

78-158-1

5925-00-161-9148

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.280 inches minimum and 0.380 inches maximum

  • Body Width

    1.987 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Fragility Factor

    moderately rugged

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    500.0 milliamperes dc second location

  • Operating Voltage Type And Rating Per Pole In Volts

    24.0 dc second location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    750.0 dc second location

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Release Characteristic

    instantaneous second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    between pole one and two

  • Nominal Thread Size

    0.375 inches

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Precious Material And Location

    contact surfaces silver

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    6 wire hook

  • Body Style

    1b multipole-single actuator type

  • Body Length

    1.562 inches maximum

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Pole Quantity

    2

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac first location

  • Trip Release Characteristic

    time delay first location

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    relay trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct and 9.000 maximum at 200 pct first location

  • Frequency In Hertz

    400.0

  • Unpackaged Unit Weight

    3.500 ounces

  • Precious Material

    silver

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...