573103-006

Circuit Breakers

CIRCUIT BREAKER

573103-006

5925-00-162-1869

5925 - Circuit Breakers

Marathonnorco Aerospace Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    8a single pole type

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    39.000 minimum at 200 pct single location and 105.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    general purpose

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 bus bar

  • Body Length

    4.740 inches minimum and 4.760 inches maximum

  • Body Width

    1.020 inches minimum and 1.040 inches maximum

  • Body Height

    2.820 inches minimum and 2.840 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    4.370 inches minimum and 4.390 inches maximum

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Frequency In Hertz

    60.0 single location

  • Unpackaged Unit Weight

    0.688 pounds

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...