67A83C342

Circuit Breakers

CIRCUIT BREAKER

67A83C342

5925-00-163-6547

5925 - Circuit Breakers

Naval Air Systems Command

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 tab, solder lug

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.900 minimum at 200 pct single location and 12.000 maximum at 200 pct single location

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Boss Height

    0.125 inches minimum and 0.135 inches maximum

  • Pole Quantity

    1

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes dc single location

  • Circuit Protection Type

    overcurrent single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc single location

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Center To Center Distance Between Terminals Parallel To Length

    1.555 inches minimum and 1.565 inches maximum

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Body Width

    0.745 inches minimum and 0.755 inches maximum

  • Fragility Factor

    moderately rugged

  • Case Material

    plastic

  • Mounting Surface To Terminal End Distance

    1.875 inches minimum and 1.885 inches maximum

  • Unpackaged Unit Weight

    2.500 ounces

  • Trip Release Method

    magnetic-hydraulic single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.655 inches minimum and 1.665 inches maximum

  • Body Style

    single pole type

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...