M55629/2-059

Circuit Breakers

CIRCUIT BREAKER

M55629/2-059

5925-00-164-2070

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unc

  • Test Data Document

    81349-mil-c-55629 specification

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Switch Terminal Type

    tab,solder lug

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.200 minimum at 200 pct and 20.000 maximum at 200 pct

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    2.800 inches maximum

  • Boss Height

    0.109 inches minimum and 0.171 inches maximum

  • Switch Contact Arrangement

    single pole,double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and 2.078 inches maximum

  • Thread Pitch Diameters

    p0.1177/p0.1214 inches

  • Specification/Standard Data

    81349-mil-c-55629/2 government specification

  • Terminal Type And Quantity

    2 threaded stud

  • Frequency In Hertz

    60.0

  • Switch Current Rating And Type In Amps

    10.0 ac and 2.0 dc

  • Switch Location And Position Designation

    internal at pole one

  • Actuator Position Designation

    at pole one

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay

  • Trip Release Method

    magnetic

  • Circuit Protection Type

    overcurrent

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Maximum Continuous Load Current Rating Per Pole

    7.0 amperes ac

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Arc Quenching Method

    magnetic blowout

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and 1.960 inches maximum

  • Case Material

    plastic

  • Body Width

    0.730 inches minimum and 0.780 inches maximum

  • Body Length

    2.510 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...