372D862G13

Circuit Breakers

CIRCUIT BREAKER

372D862G13

5925-00-165-0367

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    25000.0 ac all locations and 10000.0 dc all locations

  • Body Length

    10.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    9.531 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    400.0 amperes ac all locations and 400.0 amperes dc all locations

  • Center To Center Distance Between Terminals Parallel To Width

    2.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    9.531 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    between pole one and two

  • Trip Delay Time In Seconds Per Rated Continuous Current

    95.000 minimum at 200 pct all locations and 550.000 maximum at 200 pct all locations

  • Frequency In Hertz

    60.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Boss Height

    0.250 inches nominal

  • Terminal Type And Quantity

    4 compression

  • Body Style

    multipole-single actuator type

  • Body Height

    4.062 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Ambient Temp Rating

    50.0 deg celsius maximum all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations and 250.0 dc all locations

  • Body Width

    8.250 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.312 inches nominal

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Pole Quantity

    2

  • Circuit Protection Type

    overcurrent all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...