MILS3786-4

Switches

SWITCH,ROTARY

MILS3786-4

5930-00-165-3383

5930 - Switches

Military Specifications

SWITCH,ROTARY

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-s-3786 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Individual Section Quantity

    3

  • Contact Voltage Rating In Volts

    115.0 ac at sea level

  • Contact Switching Action

    breaks before makes each section rear

  • Err Default

    err default and err default

  • Style Designator

    tap, circular, bushing mount

  • Nominal Thread Size

    0.375 inches single mounting facility

  • Pole Quantity

    2 each section front

  • Shaft Type

    round, flatted single actuator

  • Rotor Through Connection Quantity

    2 each section

  • Hazardous Locations/Environmental Protection

    explosion proof

  • Contact Load Current Rating

    1.0 amperes inductive load dc at sea level

  • Mounting Method

    threaded bushing single mounting facility

  • First Flat Length

    0.230 inches minimum single actuator and 0.270 inches maximum single actuator

  • Overall Length

    2.427 inches minimum and 2.755 inches maximum

  • Thread Class

    2a single mounting facility

  • Nonturn Device Type

    tab at 3:00 o'clock

  • Throw Quantity

    3 each section front

  • Terminal Type

    tab, solder lug

  • Operating Temp Range

    -65.0/+125.0 deg celsius

  • Switch Contact Basic Design

    nonpile-up symmetrical

  • Thread Series Designator

    unef single mounting facility

  • Shaft Diameter

    0.248 inches minimum single actuator and 0.251 inches maximum single actuator

  • Contact Voltage Rating In Volts

    28.0 dc at sea level

  • Nonturn Device Radius

    0.360 inches minimum at 3:00 o'clock and 0.390 inches maximum at 3:00 o'clock

  • Detent Rotational Torque Range

    +1.000/+4.500 inch-pounds single actuator

  • Switch Actuator Positioning Increment

    30.0 degrees single actuator

  • Shaft Flat/Slot Angular Location

    195.0 degrees from nonturn device single actuator

  • Flat Height

    0.215 inches minimum single actuator and 0.221 inches maximum single actuator

  • Shaft Length

    0.834 inches minimum single actuator and 0.914 inches maximum single actuator

  • Switch Actuator Indexing Position Quantity

    3 single actuator

  • Overall Diameter

    1.100 inches minimum and 1.306 inches maximum

  • Switch Actuator Stop Device Type

    fixed stop single actuator

  • Contact Load Current Rating

    2.0 amperes resistive load ac at sea level and 1.0 amperes inductive load ac at sea level

  • ~1

    data on certain environmental and performance

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...