10-187896

Coils and Transformers

TRANSFORMER,POWER

10-187896

5950-00-165-3656

5950 - Coils and Transformers

Amphenol Corporation

TRANSFORMER,POWER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    4 wire lead

  • Overall Height

    1.467 inches maximum

  • Inclosure Type

    open

  • Criticality Code Justification

    feat

  • Overall Length

    1.726 inches maximum

  • Winding Function And Quantity

    1 primary single component and 1 secondary single component

  • Winding Operating Voltage

    14.00 dc volts minimum single component single primary and 30.00 dc volts maximum single component single primary

  • Overall Width

    1.182 inches maximum

  • Reliability Indicator

    not established

  • Input-Output Phase Relationship

    single phase to single phase single component

  • Winding Operating Current

    2.0 amperes dc maximum single component single secondary

  • Winding Power Rating

    5.0 watts single component single secondary

  • Winding Operating Voltage

    2.00 dc kilovolts nominal single component single secondary

  • Special Features

    ignition exciter assembly